← 1321 Allendale Ave, Akron, OH 44306 · All properties
Inspection Report - 1321 Allendale Ave - Lofty Holding 1518 Dille Road LLC - Ohio 3 Property Package, Akron, Ohio 44117.pdf
This page is a searchable text preview. Use the Dropbox link for the full original file.
| Property | 1321 Allendale Ave, Akron, OH 44306 |
|---|---|
| Folder | Inspection Report |
| Kind | |
| Updated | 2022-03-19 |
| Dropbox path | 1321 Allendale Ave, Akron, OH 44306/Inspection Report - 1321 Allendale Ave - Lofty Holding 1518 Dille Road LLC - Ohio 3 Property Package, Akron, Ohio 44117.pdf |
What This File Appears To Be
1321 Allendale Ave Akron, OH 44306 BRIAN LAPORTE Friday, January 14, 2022 Robert Hicks, OHI.2019006365 Exp.01/17/2023 A-Pro Home Inspection of Northern Ohio. 26241 Detroit Road Westlake, OH 44145 440.961.2099 Report No. 1916 REPORT OVERVIEW 1321 Allendale Ave, Akron, OH REPORT OVE ROOFING EXTERIOR APPENDIX REFERENCE January 14, 2022 STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Inspection performed by Robert Hicks of BC&S Home Solutions LLC DBA; A-Pro Home Inspections of Nort
Text Preview
1321 Allendale Ave Akron, OH 44306 BRIAN LAPORTE Friday, January 14, 2022 Robert Hicks, OHI.2019006365 Exp.01/17/2023 A-Pro Home Inspection of Northern Ohio. 26241 Detroit Road Westlake, OH 44145 440.961.2099 Report No. 1916 REPORT OVERVIEW 1321 Allendale Ave, Akron, OH REPORT OVE ROOFING EXTERIOR APPENDIX REFERENCE January 14, 2022 STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Inspection performed by Robert Hicks of BC&S Home Solutions LLC DBA; A-Pro Home Inspections of Northern Ohio KEYS USED IN THIS REPORT For your convenience, the following keys have been used in this report. MAJOR CONCERN: Denotes an improvement recommendation that is uncommon for a building of this age or location and /or that needs immediate repair or replacement. SAFETY ISSUE: Denotes an observation or recommendation that is considered an immediate safety concern. IMPROVE: Denotes a typical improvement recommendation that is common for a building of this age and location that should be anticipated or budgeted for over the short term. MONITOR: Denotes an area where further investigation by a specialized licensed contractor and/or monitoring is needed. Repairs may be necessary or desired. During the inspection, there was insufficient information or the observation was beyond the scope of the inspection. Improvements cannot be determined until further investigation or observations are made. Note: Observations listed under Discretionary Improvements are not essential repairs, but represent logical long-term improvements. IMPROVEMENT RECOMMENDATION HIGHLIGHTS The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term. Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of this report for further details on these and other recommendations. Priority Maintenance Items Roofing SLOPED ROOF FLASHINGS \ Pipe/stack flashings Condition: Leak Improve There is a leak on the pipe stack. Location: Attic Electrical DISTRIBUTION SYSTEM \ Outlets (receptacles) Condition: Test faulty on GFCI/GFI (Ground Fault Circuit Interrupter) Improve The ground fault circuit interrupter (GFCI) outlet did not respond correctly to testing during the inspection. This receptacle should be replaced. Location: Half Bathroom Condition: Improve Inoperative We are a customer service company providing unmatched integrity and education in the inspection field. Page 1 of 42