What This File Appears To Be

1518 Dille Rd, Euclid, OH *Note the building is 1520 and 1518 Units checked out: none (Occupied 1 unit ) Exterior Material masonry (brick) Proper irrigation grass and debris in gutters Driveway some wear and tear (could use a reseal ) Stairs leading to porch has some small overgrowth Sidewalk concrete with normal wear Grading pretty leveled and slightly pitched away from property Exterior structures (decks, balcony, exhaust) fairly worn, its got some areas that look to be close to half way dry r

Text Preview

1518 Dille Rd, Euclid, OH *Note the building is 1520 and 1518 Units checked out: none (Occupied 1 unit ) Exterior Material masonry (brick) Proper irrigation grass and debris in gutters Driveway some wear and tear (could use a reseal ) Stairs leading to porch has some small overgrowth Sidewalk concrete with normal wear Grading pretty leveled and slightly pitched away from property Exterior structures (decks, balcony, exhaust) fairly worn, its got some areas that look to be close to half way dry rotted Chimney if not in full use does not have a vent cap in place which will help for pest control and for keeping debris or water out. If it is in use I don’t see any clay liners which is used for venting and wear materials lined inside Roof & ventilation s hingles and has moss growth on it which will shorten roof life did not see a lot of vents for the attic up there Just a gable vent and no roof venting area for highest point . The was what seemed like a roof vent for attic but it was too close to the plumbing vent pipe which could recirculate sewer gas or fumes into the house There was what looked like an antenna mounting pole at the front which will end up being a potential roof issue in the near future with it rusting and depending on how it is mounted can quicken the wear of the roof at that area Siding vinyl siding and they also have moss and are looking weak from weathering Some sidings are showing warping and cracks from wear but not a lot of large ones (cracks longer than an inch) Fascia has some holes or openings (possible pests) D oors Did not check as it was an occupied Windows Did not check as it was occupied Interior (Did not enter as it was occupied) D oors General interior Walls Ceiling Floor Kitchen Appliances Surfaces Plumbing Bathroom Chimney, fireplace, wood stove Heating system Type Electrical Meter Subpanel Breaker panel Overall Plumbing / fuel system Attic, insulation & ventilation Health & safety concerns Nothing major to note Pests Potential pests from holes or openings on fascia especially by the soffits