← 5541 S Peoria St, Chicago, IL 60621 · All properties

Repair Estimate - 2024-10-30 - 5541 S Peoria St, Chicago, IL 60621.pdf

This page is a searchable text preview. Use the Dropbox link for the full original file.

Open full file in Dropbox

Property5541 S Peoria St, Chicago, IL 60621
FolderRepairs & Maintenance
KindPDF
Updated2024-11-11
Dropbox path08 - Repairs & Maintenance/Repair Estimate - 2024-10-30 - 5541 S Peoria St, Chicago, IL 60621.pdf

What This File Appears To Be

Square Dashboard 10/29/24, 10:34 PM NuWize Home Maintenance Meld #TYMC3GT-5541 S Peoria St Unit 1 ( NOT UNIT 2) Chicago, IL 60621 Estimate #000281 Estimate date October 29, 2024 Estimate expiration date November 28, 2024 Customer HomeRiver Group azeballos@homeriver.com 463-274-2571 6767 East Washington Street Indianopolis, IN 46240 Message Estimate to repair the duct work of a water heater for the tenant on the !rst "oor. The current duct work is tied into a chimney that is most likely plugged a

Text Preview

Square Dashboard

10/29/24, 10:34 PM

NuWize Home Maintenance
Meld #TYMC3GT-5541 S Peoria St Unit 1 ( NOT UNIT 2)
Chicago, IL 60621
Estimate #000281
Estimate date
October 29, 2024
Estimate expiration date
November 28, 2024
Customer
HomeRiver Group
azeballos@homeriver.com
463-274-2571
6767 East Washington Street
Indianopolis, IN 46240
Message
Estimate to repair the duct work of a water heater for the tenant on the !rst "oor. The current duct
work is tied into a chimney that is most likely plugged and the carbon monoxide is leaking back into
the building. The current duct work is sealed by foam which is not an acceptable sealant. There is a
PVC pipe (used for plumbing and not duct work) that is present and leads to outside the building. This
is where the duct work needs to be led. People's Gas has deemed this unsafe, tagged it, and removed
the gas line from the water heater. The repair will include removing the current duct work that vents
into the chimney, route it directly outside where the PVC pipe is using the correct materials, installing
a vent cover on the side of the building for pest control, and sealing the inside so that the CO is not
allowed back in. The hole in the chimney will have to be sealed since it is not an acceptable vent. The
gas line will have to be reinstalled for use and the water heater will be turned on and monitored for
CO leaks.
Purchase duct work materials and vent cover

https://app.squareup.com/dashboard/invoices/estimates/inve:0-ChAaWfaZ2r2-vIh0zb1dksViEMMI?currentUnitToken=7AMVZNDTGGWW7

$250.00

Page 1 of 2

Square Dashboard

10/29/24, 10:34 PM

Purchase sealing supplies

$100.00

Reinstall gas line that People's Gas removed

$100.00

Remove PVC piping to install new metal duct work

$40.00

Route duct work to the side of the building leading out

$300.00

Install vent cover on the side of the building

$150.00

Seal old hole in chimney and seal around newly routed duct work

$100.00

Turn water heater on and monitor

$40.00

Subtotal

$1,080.00

Tax

$0.00

Total

$1,080.00