← 49 Bannbury Ln, Palm Coast, FL 32137 · All properties
[BLD - Energy Calculations] 1 19 2023 - 2022070882 - 07-11-31-7012-00060-0250 - 49 BANNBURY LN - HOLI.pdf
This page is a searchable text preview. Use the Dropbox link for the full original file.
| Property | 49 Bannbury Ln, Palm Coast, FL 32137 |
|---|---|
| Folder | Property Records & Tax |
| Kind | |
| Updated | 2026-06-17 |
| Dropbox path | 11 - Property Records & Tax/Permits, Plans, Surveys/[BLD - Energy Calculations] 1 19 2023 - 2022070882 - 07-11-31-7012-00060-0250 - 49 BANNBURY LN - HOLI.pdf |
What This File Appears To Be
Reviewed for Code Compliance: 1/19/2023, PERMIT #: 2022070882 FORM R405-2022 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2022 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2022 report Input summary checklist that can be used for field verifi
Text Preview
Reviewed for Code Compliance: 1/19/2023, PERMIT #: 2022070882 FORM R405-2022 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2022 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2022 report Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) A completed 2022 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) . 1/18/2023 4:03:43 PM Page 1 of 1 01/19/2023 11:29 am IP:[10.10.250.10] FORM R405-2022 Supplement FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Street: City, State, Zip: Owner: Design Location: Holiday Builders Foxtail 49 Bannbury Lane 49 Bannbury Lane Palm Coast , FL, 32137 FL, Daytona Beach 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area above grade (ft²) Conditioned floor area below grade (ft²) 1552 0 7. Windows(123.1 sqft.) Description a. U-Factor: Dbl, U=0.35 SHGC: SHGC=0.22 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: Area 2 123.13 ft 8. Skylights U - Fa c t o r : ( AVG ) SHGC(AVG): Description N/A N/A 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A Insulation R= 0.0 R= R= 2 ft 2 ft Builder Name: Holiday Builders Permit Office: Permit Number: Jurisdiction: County: Flagler(Florida Climate Zone 2) 10. Wall Types(1477.3 sqft.) Insulation Area 2 a. Concrete Block - Int Insul, Exterior R=4.1 1141.30 ft 2 b. Frame - Wood, Adjacent R=13.0 336.00 ft c. N/A d. N/A 11. Ceiling Types(1552.0 sqft.) Insulation Area 2 a. Flat ceiling under att (Vented) R=30.0 1552.00 ft b. N/A c. N/A 2 12. Roof(Comp. Shingles, Vented) Deck R=0.0 1681 ft 2 13. Ducts, location & insulation level R ft a. Sup: Attic, Ret: Main, AH: Main 6 310 b. c. 14. Cooling Systems k Bt u / h r Efficiency a. Central Unit 28.4 SEER2:14.30 1.333 ft 0.220 Area 2 N/A ft 15. Heating Systems a. Electric Heat Pump Area 2 1552.00 ft 2 ft 2 ft 16. Hot Water Systems a. Electric k Bt u / h r Efficiency 28.6 HSPF2:7.50 Cap: 50 gallons EF: 0.950 b. Conservation features None Pstat 17. Credits Glass/Floor Area: 0.079 Total Proposed Modified Loads: Total Baseline Loads: I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. Ed Wolfe PREPARED BY: _________________________________ 2023.01.18 16:04:38 -05’00 DATE: _________________________________________ I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: __________________________________ DATE: _________________________________________ 1/19/23 38.51 42.22 PASS Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: ____________________________ DATE: _________________________________________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Default duct leakage does not require a Duct Leakage Test Report. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/18/2023 4:03:43 PM EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 1