Reviewed for Code Compliance: 1/19/2023, PERMIT #: 2022070882 FORM R405-2022 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2022 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2022 report Input summary checklist that can be used for field verifi

Text Preview

Reviewed for Code Compliance: 1/19/2023, PERMIT #: 2022070882

FORM R405-2022

RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST

Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method

Applications for compliance with the 2022 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
This checklist
Form R405-2022 report
Input summary checklist that can be used for field verification (usually four pages/may be greater)
Energy Performance Level (EPL) Display Card (one page)
HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
Mandatory Requirements (five pages)
Required prior to CO:
Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page)
A completed 2022 Envelope Leakage Test Report (usually one page); exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
2020 Duct Leakage Test Report - Performance Method (usually one page)
.

1/18/2023 4:03:43 PM

Page 1 of 1

01/19/2023 11:29 am IP:[10.10.250.10]

FORM R405-2022 Supplement

FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Street:
City, State, Zip:
Owner:
Design Location:

Holiday Builders Foxtail 49 Bannbury Lane
49 Bannbury Lane
Palm Coast , FL, 32137
FL, Daytona Beach

1. New construction or existing

New (From Plans)

2. Single family or multiple family

Detached

3. Number of units, if multiple family

1

4. Number of Bedrooms

3

5. Is this a worst case?

No

6. Conditioned floor area above grade (ft²)
Conditioned floor area below grade (ft²)

1552
0

7. Windows(123.1 sqft.) Description
a. U-Factor:
Dbl, U=0.35
SHGC:
SHGC=0.22
b. U-Factor:
N/A
SHGC:
c. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:

Area
2
123.13 ft

8. Skylights
U - Fa c t o r : ( AVG )
SHGC(AVG):

Description
N/A
N/A

9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A

Insulation
R= 0.0
R=
R=

2

ft

2

ft

Builder Name: Holiday Builders
Permit Office:
Permit Number:
Jurisdiction:
County:
Flagler(Florida Climate Zone 2)
10. Wall Types(1477.3 sqft.)
Insulation
Area
2
a. Concrete Block - Int Insul, Exterior R=4.1
1141.30 ft
2
b. Frame - Wood, Adjacent
R=13.0
336.00 ft
c. N/A
d. N/A
11. Ceiling Types(1552.0 sqft.)
Insulation
Area
2
a. Flat ceiling under att (Vented)
R=30.0 1552.00 ft
b. N/A
c. N/A
2
12. Roof(Comp. Shingles, Vented) Deck R=0.0
1681 ft
2
13. Ducts, location & insulation level
R
ft
a. Sup: Attic, Ret: Main, AH: Main
6 310
b.
c.
14. Cooling Systems
k Bt u / h r
Efficiency
a. Central Unit
28.4 SEER2:14.30

1.333 ft
0.220
Area
2
N/A ft

15. Heating Systems
a. Electric Heat Pump

Area
2
1552.00 ft
2
ft
2
ft

16. Hot Water Systems
a. Electric

k Bt u / h r
Efficiency
28.6 HSPF2:7.50

Cap: 50 gallons
EF: 0.950

b. Conservation features
None
Pstat

17. Credits
Glass/Floor Area: 0.079

Total Proposed Modified Loads:
Total Baseline Loads:

I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.

Ed Wolfe

PREPARED BY: _________________________________

2023.01.18 16:04:38 -05’00

DATE: _________________________________________
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: __________________________________
DATE:
_________________________________________
1/19/23

38.51
42.22

PASS

Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL: ____________________________
DATE: _________________________________________

- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Default duct leakage does not require a Duct Leakage Test Report.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).

1/18/2023 4:03:43 PM EnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software