← 428 Cross St, Akron, OH 44311 · All properties
Inspection Report - 428 Cross St, Akron, OH 44311.pdf
This page is a searchable text preview. Use the Dropbox link for the full original file.
| Property | 428 Cross St, Akron, OH 44311 |
|---|---|
| Folder | Inspection Report |
| Kind | |
| Updated | 2022-01-19 |
| Dropbox path | 09 - Inspection Report/Inspection Report - 428 Cross St, Akron, OH 44311.pdf |
What This File Appears To Be
428 Cross St Akron, OH 44311 BRIAN LAPORTE Tuesday, November 23, 2021 Robert Hicks, OHI.2019006365 Exp.01/17/2023 A-Pro Home Inspection of Northern Ohio. 26241 Detroit Road Westlake, OH 44145 440.961.2099 Report No. 1792 REPORT OVERVIEW 428 Cross St, Akron, OH REPORT OVE ROOFING APPENDIX REFERENCE November 23, 2021 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Inspection performed by Robert Hicks of BC&S Home Solutions LLC DBA; A-Pro Home Inspections of Northern Ohio
Text Preview
428 Cross St Akron, OH 44311 BRIAN LAPORTE Tuesday, November 23, 2021 Robert Hicks, OHI.2019006365 Exp.01/17/2023 A-Pro Home Inspection of Northern Ohio. 26241 Detroit Road Westlake, OH 44145 440.961.2099 Report No. 1792 REPORT OVERVIEW 428 Cross St, Akron, OH REPORT OVE ROOFING APPENDIX REFERENCE November 23, 2021 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Inspection performed by Robert Hicks of BC&S Home Solutions LLC DBA; A-Pro Home Inspections of Northern Ohio KEYS USED IN THIS REPORT For your convenience, the following keys have been used in this report. MAJOR CONCERN: Denotes an improvement recommendation that is uncommon for a building of this age or location and /or that needs immediate repair or replacement. SAFETY ISSUE: Denotes an observation or recommendation that is considered an immediate safety concern. IMPROVE: Denotes a typical improvement recommendation that is common for a building of this age and location that should be anticipated or budgeted for over the short term. MONITOR: Denotes an area where further investigation by a specialized licensed contractor and/or monitoring is needed. Repairs may be necessary or desired. During the inspection, there was insufficient information or the observation was beyond the scope of the inspection. Improvements cannot be determined until further investigation or observations are made. Note: Observations listed under Discretionary Improvements are not essential repairs, but represent logical long-term improvements. IMPROVEMENT RECOMMENDATION HIGHLIGHTS The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term. Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of this report for further details on these and other recommendations. Priority Maintenance Items Structure ROOF FRAMING \ Sheathing Condition: Suspected Mold Growth Improve Evidence of condensation (in the form of likely fungal growth) was observed on the underside of the roof sheathing in the attic. The identification of the organism(s) is beyond the scope of this home inspection. It is recommended that a Certified Industrial Hygienist be engaged to Further evaluate this condition. Location: Attic Apt. 1 and 2 THE SCOPE OF THE INSPECTION This report is prepared in accordance with Ohio Revised Code 4764 and rules adopted thereunder. All components designated for inspection in the ISHI Inspector Standards are inspected, except as may be noted in the Limitations of Inspection sections within this report. The ISHI Inspector Standards can be found at the end of this report and are made part of the inspection. This inspection is visual only. A representative sample of building components is viewed in areas that are accessible at the time of the inspection only. No destructive testing or dismantling of building components is performed. Each mechanical system which conveys as part of the property and specifically listed as having been tested was observed to be in normal working condition at the time of inspection, unless one or more deficiencies for the listed system is reported. Latent defects may still exist, and evaluation of any system is limited by the conditions during the inspection and the scope defined by the ISHI Home Inspection Standards of Practice. We are a customer service company providing unmatched integrity and education in the inspection field. Page 1 of 35