← 3178 W 41st St, Cleveland, Ohio 44109 · All properties

Inspection Report - 3178 W 41st St - Lofty Holding 41st St & Silk Ave LLC - 3178 W 41st St, Cleveland, OH 44109.pdf

This page is a searchable text preview. Use the Dropbox link for the full original file.

Open full file in Dropbox

Property3178 W 41st St, Cleveland, Ohio 44109
Folder(root)
KindPDF
Updated2022-01-26
Dropbox pathInspection Report - 3178 W 41st St - Lofty Holding 41st St & Silk Ave LLC - 3178 W 41st St, Cleveland, OH 44109.pdf

What This File Appears To Be

3178 W 41st St Cleveland, OH 44109 BRIAN LAPORTE Wednesday, December 22, 2021 Robert Hicks, OHI.2019006365 Exp.01/17/2023 A-Pro Home Inspection of Northern Ohio. 26241 Detroit Road Westlake, OH 44145 440.961.2099 Report No. 1861 REPORT OVERVIEW 3178 W 41st St, Cleveland, OH REPORT OVE ROOFING EXTERIOR APPENDIX REFERENCE December 22, 2021 STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Inspection performed by Robert Hicks of BC&S Home Solutions LLC DBA; A-Pro Home Inspections of

Text Preview

3178 W 41st St
Cleveland, OH 44109
BRIAN LAPORTE

Wednesday, December 22, 2021

Robert Hicks, OHI.2019006365 Exp.01/17/2023

A-Pro Home Inspection of Northern Ohio.
26241 Detroit Road
Westlake, OH 44145

440.961.2099

Report No. 1861

REPORT OVERVIEW
3178 W 41st St, Cleveland, OH
REPORT OVE

ROOFING

EXTERIOR

APPENDIX

REFERENCE

December 22, 2021
STRUCTURE

ELECTRICAL

HEATING

COOLING

INSULATION

PLUMBING

INTERIOR

Inspection performed by Robert Hicks of BC&S Home Solutions LLC DBA; A-Pro Home Inspections of Northern Ohio
KEYS USED IN THIS REPORT
For your convenience, the following keys have been used in this report.
MAJOR CONCERN: Denotes an improvement recommendation that is uncommon for a building of this age or location
and /or that needs immediate repair or replacement.
SAFETY ISSUE: Denotes an observation or recommendation that is considered an immediate safety concern.
IMPROVE: Denotes a typical improvement recommendation that is common for a building of this age and location that
should be anticipated or budgeted for over the short term.
MONITOR: Denotes an area where further investigation by a specialized licensed contractor and/or monitoring is
needed. Repairs may be necessary or desired. During the inspection, there was insufficient information or the
observation was beyond the scope of the inspection. Improvements cannot be determined until further investigation or
observations are made.
Note: Observations listed under Discretionary Improvements are not essential repairs, but represent logical long-term
improvements.
IMPROVEMENT RECOMMENDATION HIGHLIGHTS
The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term.
Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of
this report for further details on these and other recommendations.
Priority Maintenance Items

Electrical
DISTRIBUTION SYSTEM \ Outlets (receptacles)
Condition: Faulty
Safety Issue
Various outlets tested faulty at time of inspection. These circuits should be further evaluated.
Location: Throughout The House

Plumbing
WASTE PLUMBING \ Traps - performance
Condition: Leak
Improve
The leak on the drain line should be repaired.
Location: Kitchen
THE SCOPE OF THE INSPECTION
This report is prepared in accordance with Ohio Revised Code 4764 and rules adopted thereunder.
All components designated for inspection in the ISHI Inspector Standards are inspected, except as may be noted in the
Limitations of Inspection sections within this report. The ISHI Inspector Standards can be found at the end of this report

We are a customer service company providing unmatched integrity and education in the
inspection field.

Page 1 of 37