What This File Appears To Be

Reviewed for Code Compliance: 2/28/2023, PERMIT #: 2023021025 City of Palm Coast Product Approval Submittal Affidavit (Inspire) Code Version 2020 The products listed herein have been evaluated for compliance with the Florida Building Code in accordance with the product approval requirements of Florida Statute Chapter 553.842 and Florida Administrative Code Chapter 9N‐3 and based upon testing, comparative,or rational analysis, or a combination thereof said products comply with the minimum require

Text Preview

Reviewed for Code Compliance: 2/28/2023, PERMIT #: 2023021025

City of Palm Coast Product Approval Submittal Affidavit
(Inspire)

Code Version 2020

The products listed herein have been evaluated for compliance with the Florida Building Code in accordance with the product approval requirements of Florida Statute
Chapter 553.842 and Florida Administrative Code Chapter 9N‐3 and based upon testing, comparative,or rational analysis, or a combination thereof said products comply
with the minimum requirements of the Florida Building Code for the puroses intended
Product

Model#

Mfg

Attachment Method

Max Design
Pressures

application #

Garage Door 8' x 7'

73

Clopay

Attached to Jamb w 5/16" x 1‐5/8" lag screws in door bracket to 2 x 6 anchored by 8" J‐bolts (4) Ea. Side Blk ‐ 1/2" x 3" lag. 1
5/8" emb.

+25/‐32

FL15279.12

Garage Door 16' x 7'

73W5

Clopay

Attached to Jamb w 5/16" x 1‐5/8" lag screws in door bracket to 2 x 6 anchored by 8" J‐bolts (4) Ea. Side Blk ‐ 1/2" x 3" lag. 1
5/8" emb.

30/‐30

FL15279.52

Entry Door 3068
and 3080

Smooth Star

Thermatru

#10 x 2.5" LG. PFH Wood Screw to 2x wood buck W/1.15" min EMB.Max 6" from corners. SEE DETAILS FOR ATTACHMENT OF
2X WOOD BUCK TO BLOCK

+67 / ‐67

FL20468.1

SH Windows
(insulated glass) w/
1x Bucks

3540

MI
Windows
and Doors

WINDOWS UP TO 36" x 74"
(Per fastening Schedule) 3/16" x 2 1/4" Tapcons W/ 1‐1/4" Min. Embedment

+35 /
‐50

FL17676.8

SH Windows
(insulated glass) w/
1x Bucks

3500HP

MI
Windows
and Doors

WINDOWS OVER 36" WIDE
(Per fastening Schedule) 3/16" x 2 1/4" Tapcons W/ 1‐1/4" Min. Embedment

+50 / ‐50

FL17894.4

Windows, Fixed
w/ 1x bucks
(Insulated Glass)

3500

MI
Windows
and Doors

(Per fastening schedule) 3/16" x 3‐1/4" Tapcons (w‐1 1/4" Min embedment)

+50 / ‐50

FL18644.2

Windows, Fixed
w/ 2x Bucks
(Insulated Glass)

3500

MI
Windows
and Doors

#6 x 1‐5/8" wood screw (min 1‐1/4" penetration)
Jambs: 2‐1/2" from corners not more than 11" on center Head/Sill: 3‐1/2" from corners and not more than 11" on center

+70 /
‐70

FL18644.1

Mullions

M1926

MI
Widows and
Doors

Frame‐(2) #10 x 1‐1/2" WS
Block‐(2) 1/4" x 1‐1/2" Tapcons w/ 1‐1/4" min. Embedment
Window Frame to Mull ‐ #10 x 1‐1/2" PFH SMS: 3" mininum from each end and 24" maximum o.c. throughout

+50 / ‐50

FL18504.1 Horizontal
FL18504.2 Vertical

Sliding Glass Door,
80" height
(2 Panel)

420

MI
Windows
and Doors

#10 wood screws to 2x wood buck w/ 1‐3/8" min embedment. #10 6" from corneres and 24" oc mac. All other holes to be
#8 wood screw. 3/16" Tapcons w/ 1‐1/4" min embedment @ Threshold SEE DETAILS FOR ATTACHMENT OF 2X WOOD BUCK
TO BLOCK

+35 / ‐35

FL15332.2

SH Windows

1500

SH=#8 wood screws min. 1‐1/2" embedment and 7/16" from Edge

+50 / ‐50

FL 16103.1

SH Windowns (fixed)

1500

PlyGem
Windows
PlyGem
Windows

Fixed =#8 wood screws min. 1‐1/2" embedment and 3/8" from Edge

+55 / ‐55

FL 16104.1

4700

PlyGem
Windows

Use 3/16" ELCO Ultracons or 3/16" ITW tapcons of sufficient length to achieve 1 3/4" min. embedment

+50 / ‐50

FL 14634.1

Mullions

6063‐T6

PlyGem
Windows

Use 3/16" or 1/4" ITW tapcon or ELCO ultracon screws of sufficient length to achieve minimun embedment of 1 1/4" into
concrete/masonary substrate

na

FL 16118‐R4

Hurricane Panels

28ga and 24ga
Storm Panels,

Town &
Country

Block ‐ 1/4"x 20 AP Lead Anchor @ 12" O.C. w 7/8" Embedment Frame ‐ 1/4"x 20 Panelmate @ 12" O.C. w/ 1‐7/8"
Embedment Various angle materials per installation sheets as needed.

+50 / ‐50

FL7989.1

Sliding Glass Door,
80" height (2 Panel)

Soffit

Soffit

Alside

2T Vinyl Soffit

157.0 / ‐54.9

FL 15272.1

Truss Strap

Meta18

Simpson

Nails/Bolts 8‐10 (16‐16d)

NA

FL11473.9

Truss Seat Plate

Model#
150026090

Mitek

Attached to Truss Per Truss Company

NA

Model #
150015080

Hardie Board Shakes

Siding

HardieShingle Siding fastener types, fastening schedule, and installation shall be in accordance with CAE Engineering Reports
No.:2001‐10.2.3 or 2001‐10.2.4. Consult the HardieShingle product installation instructions

NA

FL13192.4

Hardie Board Trim

Siding

HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with CAE Engineering
Reports No.:2001‐10.2.1, 2001‐10.2.2, 2001‐10.2.3. Consult the HardiePlank product installation instructions

NA

FL13192.2

Cemplank Siding

Siding

Cemplank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with CAE Engineering Reports
No.:2001‐10.2.1, 2001‐10.2.2, 2001‐10.2.3. Consult the Cemplank product installation instructions

NA

FL13192.1

Roof Sheathing

Weather Logic

Roof Sheathing

Zip Wall

Huber

Roof Underlayment

Gardner
Ashpalt Corp

Gardner
Ashpalt Corp

Roof Underlayment

Rhino

Owens
Corning

James
Hardie
Building
James
Hardie
Building
Products
James
Hardie
Building
Products
Louisiana
Pacific

Combination Roof Sheathing and roof underlayment‐sheathing installation and tape per manufacturers installation
guidelines.
Combination Roof Sheathing and roof underlayment‐sheathing installation and tape per manufacturers installation
guidelines.

na

FL 30464‐R1

na

FL 17146.1‐R5

Weather Armor SB‐1 SEE DETAILS FOR ATTACHMENT

na

FL 27076.16

End (Vertical) laps shall be minimum 6 inches and side (horizontal) laps shall be minimum 4‐inches

na

FL15216.1‐R8

8/22/2022

02/17/2023 09:02 am IP:[10.10.250.10] Packet No: 79683