What This File Appears To Be

VILLAGE OF DIXMOOR Inspection Form FAIL Inspection ID: XMD-DYL-2QT5 Inspector: Cleo Butler RESULT PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS FAIL PASS PASS PASS PASS PASS PASS PASS FAIL PASS PASS PASS PASS Property Address: 25 CIRCLE DRIVE Inspection Date: 04/26/2024 CODE DESCRIPTION Inspection Type : Rental P2803.6.1 IRC Discharge pipe serving pressure-relief valve on water heater no higher than 6inches above the 2012 floor or waste pan P2903.9.3 IRC An individual shutoff valve

Text Preview

VILLAGE OF DIXMOOR
Inspection Form

FAIL
Inspection ID: XMD-DYL-2QT5
Inspector: Cleo Butler
RESULT
PASS
PASS
PASS

PASS
PASS
PASS

PASS
PASS
PASS
PASS

PASS
PASS
FAIL
PASS
PASS
PASS
PASS

PASS
PASS
PASS
FAIL
PASS
PASS
PASS
PASS

Property Address: 25 CIRCLE DRIVE
Inspection Date: 04/26/2024

CODE

DESCRIPTION
Inspection Type : Rental
P2803.6.1 IRC
Discharge pipe serving pressure-relief valve on water heater no higher than 6inches above the
2012
floor or waste pan
P2903.9.3 IRC
An individual shutoff valve shall be required on the fixture supply pipe to each plumbing
2012
fixture other then bathtubs and showers
P3201.5 IRC 2012 The following types of traps are prohibited: 1. Bell traps, 2. Separate fixture traps with interior
partitions, except those lavatory traps made of plastic, stainless steel or other corrosionresistant materials, 3. "S" traps, 4. Drum traps, 5. Trap designs with moving parts.
State Law
Disconnect storm water system from sanitary sewer
110.12 NEC Sec. Replace broken, severely painted or two prong recepticles
C
406.12 NEC 2011 Tamper-Resistant Receptacles required in all areas specified in 210.52. Except appliances, a
single receptacle or a duplex receptacles for two appliances located within a dedicated space
for each appliance that in normal use is not easily moved.
R314/315 IRC
120V Interlinked smoke and carbon/carbon monoxide detectors. Required locations
2012
determined by 2012 IRC and NFPA 720
E4003.12 IRC
Globe protected light fixtures in closets where fixtures exist
2012
605.2 IMPC 2012 Main electrical panel to be serviced by licensed electrician
NEC 210.8
Ground-fault circuit interrupters (GFCI) protection shall be provided for all 125-volt, 15 and
20 amp recepticle outlets installed outdoors, in boathouses, garages,unfinished accessory
buildings, crawl spaces at or below grade level, unfinished basements,bathrooms, at kitchen
countertops and within 6ft of the outside edge of all other sinks.
NEC 230.24 2011 Clearances Overhead service conductors
605.2 IPMC 2012 Label circuits in electrical panel
603.1 IPMC 2012 Furnace needs servicing by licensed technician
R310.1.3
Emergency Escape and Rescue
R311.7.8 IRC
Handrails shall be provided on at least one side of each flight of stairs with four or more risors
2012
R302.7 IRC 2012 Enclosed accessible space under stairs shall have walls, under-stair surface and any
soffitsprotected on the enclosed side with 1/2 inch gypsum board.
R302.5.1 IRC
Attached Garage (Door) shall be equipped with solid wood doors not less than 13/8 inches(35
2012
mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm)thick
or 20-minute fire rated doors, equipped with a self closing device.
303.3 IMPC
Prohibited Locations - Fuel fired appliances shall not be located in, or obtain combustion air
from basements.
304.7 IMC 2012 Private Garages - Appliances located in private garages and carports shall be installed with a
minimum clearance of 6 feet above the floor
311.7.5.1 IRC
Risers - The maximum riser height shall be 7 1/4 inches. The greates riser height within any
flight of stairs shall not exceed the smallest by nore than 3/8 inch.
304.14 IPMC
Insect screens shall be tight fitting.
302.3 IPMC
Sidewalks - All sidewalks and walkways and similar areas shall be kept in proper state of
repair, and maintained free from hazardous conditions
302.4 IPMC 2012 Weeds. All premises exterior property shall be maintained free from grass, weeds, weed trees
in acc
302.7
Accessory Structures- All accesory structures shall be maintained structurally sound and in
good repair
604.3 IPMC 2012 Electrical system a safety hazard. All switches and recepticles require covers

Page 1/2

VILLAGE OF DIXMOOR
Inspection Form

FAIL
PASS

306.3 IMPC

Exterior Surfaces - Including windows and doors, shall be maintained in good, clean and
sanitary condition. Peeling, flaking or abraded paint shall be repaired, removed or coverd.
PASS
304.10 IPMC
Stairway, decks, porches and balconies, shall be maintained structurally sound and in good
repair
PASS
305.3 IPMC 2012 Remove all Mold and Water damaged building materials
NO
Plumbing Permit Required
NO
Electrical Permit Required
YES
General Permit Required
YES
HVAC Permit Required
Inspector Signature

Owner Signature

ADDITIONAL NOTES
Label all breakers on panel in breaker box cut grass, remove all weeds, front and rear yard area

Page 2/2