Home Inspection Report Prepared exclusively for Lofty AI, Inc. PROPERTY INSPECTED: 1315 East 114th Street Cleveland, OH 44106 Date of Inspection: 11/04/2022 Inspection No. 24729-1-9108 INSPECTED BY: INSPECTOR: Safe Home Promise, LLC David Schultz 134 College St david.schultz@pillartopost.com Suite B, Wadsworth OH (330) 334-3374 ferguson.team@pillartopost.com (330) 334-3374 Each office is independently owned and operated 24729-1-9108 1315 East 114th Street, Cleveland, OH 44106 11/04/2022 REPORT S

Text Preview

Home Inspection Report
Prepared exclusively for

Lofty AI, Inc.

PROPERTY INSPECTED:

1315 East 114th Street
Cleveland, OH 44106
Date of Inspection: 11/04/2022
Inspection No. 24729-1-9108

INSPECTED BY:

INSPECTOR:

Safe Home Promise, LLC

David Schultz

134 College St

david.schultz@pillartopost.com

Suite B, Wadsworth OH

(330) 334-3374

ferguson.team@pillartopost.com
(330) 334-3374
Each office is independently owned and operated

24729-1-9108

1315 East 114th Street, Cleveland, OH 44106

11/04/2022

REPORT SUMMARY
This summary is not the entire report. The complete report may include additional information of concern to the
client. It is recommended that the client read the entire report.

3.0

EXTERIOR

3.2

Wall Surface
3.2.1 Some damaged siding noted. Recommend replacement/sealing to reduce possible moisture/pest
intrusion and for intended appearance.
3.2.3 Wood rot identified in areas throughout the exterior. Further evaluation is recommended to determine
the extent of potential damaged and repair as needed to prevent future concerns.

3.3

Eaves / Fascia / Soffit
3.3.1 Fascia damage is visible although most of the fascia is concealed by the gutters. Recommend further
evaluation to determine the full extent of damage and repair as required.

3.4

Trim
3.4.1 Wood trim around exterior is in need of maintenance. Recommend repairing (as/if needed), scraping,
prepping, recaulking and repainting to reduce the potential for further deterioration.

3.5

Porch(es)
3.5.1 Structural settlement noted to the porch and porch roof . Recommend a qualified contractor replace the
damaged sections and repair as needed to reduce further deterioration and provide intended support.
(Exterior Front)
3.5.2 Provide handrail(s) on the stairs for safety. The current front porch hand rail is loose. The rear steps are
missing handrails.
Exterior Back
Exterior Front

3.6

Exterior Storage Room
3.6.1 Structure of the exterior storage room is poor. Most framing is rotted or inadequate. Recommend
removing the structure. (Exterior Back)

4.0

ROOFING SYSTEM

4.5

Roof Drainage
4.5.2 Roof gutters are damaged, plugged with leaves and debris or missing. Proper roof drainage is critical to
controlling moisture near the home. Consultation from a qualified contractor to make recommendations to
ensure adequate function and drainage.

6.0

STRUCTURE

6.2

Structure General Comments
6.2.2 Potential wood destroying insect damage was noted. Recommend further evaluation and treatment by
a pest control professional to prevent further damage.

6.5

Floor Structure
6.5.1 Settled floor joist noted. Recommend evaluation by a contractor and support of joist(s)as directed to
reduce settlement and for proper support.
Basement
Stairwell
6.5.2 Possible mold growth noted to exposed floor joists. Recommend further evaluation and treatment by a
qualified mold remediation professional to reduce potential health concerns. (Basement)

6.6

Wall Structure
6.6.1 The wood-frame wall(s) show evidence of mechanical damage. Have this damage repaired to ensure
serviceability.
Hallway
Third Floor

David Schultz